50% OFF! Hot items selling fast—Grab them before they're gone!
The Fluke 368 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.The Fluke 368 FC has a large 40 mm diameter jaw for work with large conductors. The clamps jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.The 368 FC also offers wireless data connectivity via Fluke Connect. As part of Fluke Connect the industrys largest system of software and more than 40 wireless test tools the 368 FC allows you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures.IncludesSoft caseSafety manualBatteries: 2 AAFeaturesTrue-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms40 mm jaw openingHighest resolution of 1 A, measure up to 60 ASelectable filter function removes unwanted noiseMax/Min/Average readings and hold functionForward-facing LED worklight for use in dark wiring cabinetsBacklit display; auto backlight off and auto power off for extended battery lifeCAT III 600V safety ratingInternal Memory Logging: up to 65,000 measurement pointsSpecificationsDisplay (LCD): Digital readout: 3300 countDisplay refresh rate: 4 times / secMaximum conductor diameter: 40 mmDimensions: 234 x 101 x 46 mmWeight: 500 gBattery: 2 AA, IEC LR6, NEDA 15A, alkalineBattery life: Expected battery life, without using backlight and spotlight, is more than 150 hoursAutomatic shut-down: Meter automatically shuts down after 15 minutes of inactivityAccuracy SpecificationsMeasurement function: Alternating currentAC ampere range: 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 ASelection: mA / A manual3 mA / 30 mA / 300 mA automatic selection3 A / 30 A / 60 A automatic selectionRange/Resolution:3 mA / 0.001 mA30 mA / 0.01 mA300 mA / 0.1 mA3 A / 0.001 A30 A / 0.01 A60 A / 0.1 AAccuracy (filter activated 40 to 70 Hz, filter off 40 to 1 kHz):3 mA 30 A: 1% + 5 digits60 A: 2% + 5 digitsFrequency: 40 Hz to 1 kHzCrest factor: 3General safety:IEC 61010-1Pollution Degree 2Measurement safety:IEC 61010-2-032CAT III 600 V / CAT IV 300 VOperating temperature: -10C to +50CStorage temperature: -40C to +60COperating humidity: Non-condensing (<10C)90% relative humidity (10C to 30C)75% relative humidity (30C to 40C)45% relative humidity (40C to 50C)Protection class: IEC 60529 IP30 (jaw closed)Operating altitude: 2000 mStorage altitude: 12,000 mCurrent sensor action category: IEC 61557-13, Class 2, 30 A/mElectromagnetic compatibility (EMC): IEC 61326-1